← Back to articles

Prolonged Nasoesophageal Feeding Tubes Cause Cervical Esophageal Strictures in Cats

Updated 2026-11-12

Article coverImage source

Three cats with suspected hepatic lipidosis developed severe, focal cervical esophageal strictures after nasoesophageal (NE) tubes were left in place for 24–37 days—far longer than the 4–5 day window traditionally considered safe. Endoscopic evaluation confirmed strictures at the C4–C6 vertebral level, and one cat recovered after a series of balloon dilatations, while the others suffered regurgitation, aspiration pneumonia, or were lost to follow‑up.


Standard use of nasoesophageal tubes in feline patients

In small‑animal practice, NE tubes are a quick, minimally invasive way to deliver enteral nutrition to cats that are not eating voluntarily. The tubes are typically 6 French in diameter, 50 cm long, and placed through the ventral nasal meatus into the distal thoracic esophagus. Because they can be inserted with little or no sedation, they are favored for short‑term support—generally no more than four to five days—after which clinicians transition to a more durable device (esophagostomy or gastrostomy tube) if the cat still requires supplemental feeding.

When prolonged nutritional support is needed, guidelines already recommend moving to larger‑bore, surgically placed tubes that are better tolerated over weeks to months. The three cases reported by Cho et al. (2026) illustrate what can happen when this recommendation is not followed.


Clinical picture that prompted tube placement

All three cats were admitted with a 5‑ to 7‑day history of marked hyporexia or anorexia, lethargy, and jaundice. Blood work showed hyperbilirubinemia and markedly elevated hepatic enzymes (ALT, AST, ALP), leading to a presumptive diagnosis of feline hepatic lipidosis. Voluntary intake remained below 20–25 % of each cat’s calculated resting energy requirement, so the veterinary team initiated enteral feeding via a 6‑French DEHP‑free NE tube.

Feeding began at 25–30 % of the calculated energy need and was titrated up over four to five days to 100 % of daily requirements. Supportive care included IV fluids, maropitant, esomeprazole, silymarin, and SAMe. Despite improvement in liver values, none of the cats regained sufficient appetite, prompting clinicians to keep the NE tube in place longer than usual.


Duration of tube placement and re‑intubation

Each cat received two consecutive periods of NE tube feeding because the first tube was removed after 10–14 days to assess oral intake. Persistent anorexia led to a second tube being placed. The cumulative time the tubes remained in the esophagus ranged from 24 days (Case 2) to 37 days (Case 3)—approximately five to nine times the standard duration.


Onset of regurgitation after tube removal

Regurgitation began within 24–72 hours after the final tube was removed in all three cats:

CaseCumulative NE tube daysDay tube removedOnset of regurgitation
1 – 6‑yr neutered male Persian24–38 days*Hospital day 3824 h
2 – 2‑yr spayed female Korean Shorthair24 daysHospital day 273 days
3 – 8‑yr spayed female Korean Shorthair37 daysHospital day 412 days

*The report notes the tube was finally removed on hospital day 38 for Case 1, placing the cumulative duration at the upper end of the series.

The rapid appearance of regurgitation suggested an obstructive process rather than simple postoperative dysphagia.


Endoscopic confirmation of cervical strictures

Esophagoscopy performed 2–18 days after the regurgitation began revealed a uniform, circumferential stricture located between the fourth and sixth cervical vertebrae (C4–C6) in every cat. The lumen was narrowed to:

The mucosa appeared fibrotic, pale, and occasionally hemorrhagic, with no evidence of an intraluminal mass. Contrast esophagography and fluoroscopy in Case 3 confirmed pooling of contrast cranial to the stenotic segment, corroborating the mechanical obstruction.

These findings are notable because previously reported benign esophageal strictures in cats have most often involved the middle or distal thoracic esophagus (78–90 % of cases). Strictures confined to the cervical esophagus had not been described in felines before this series.


Outcomes and interventions


Proposed mechanisms for cervical stricture formation

Cho et al. (2026) offered a multifactorial hypothesis:

  1. Reflux alone is insufficient – All cats were receiving esomeprazole, a proton‑pump inhibitor, yet strictures developed in the cervical esophagus, a region not typically affected by gastro‑esophageal reflux, which usually targets the distal thoracic segment.
  2. Mechanical pressure and friction – Continuous contact between the tube’s distal tip and the esophageal wall during swallowing and neck movement may cause localized ulceration, followed by fibrosis.
  3. Anatomical bottleneck at C4–C6 – The cervical inlet is a naturally narrowed zone where the esophagus passes the thoracic inlet. This anatomic restriction could concentrate shear forces from the tube, making the mucosa especially vulnerable.

The authors caution that, because the series includes only three patients and lacks a control group, causation cannot be definitively proven. The exact duration at which mucosal injury becomes irreversible remains unknown, as does the contribution of underlying hepatic disease, systemic inflammation, or tube material characteristics (despite being DEHP‑free).


Clinical implications and unanswered questions

The case series underscores a clear association between prolonged NE tube placement (≥ 24 days) and focal cervical esophageal strictures in cats. It reinforces existing recommendations to limit NE tubes to a maximum of four to five days and to transition early to esophagostomy or gastrostomy tubes when longer‑term feeding is anticipated.

However, several gaps persist:

Future prospective studies should quantify the risk, explore preventive measures, and evaluate the efficacy of endoscopic dilatation versus surgical alternatives in the feline population.


References: